Want to learn more?

Call us

Email us

Request support

How to use PX / PX Q, Hermes+ / HERMES Q as a printer without digital signals?

The following instruction enables the operator to control the PX / PX Q, Hermes+ / HERMES Q like a standard printer without using the digital interface!

   1. Choose in your label software the printer mode: "none"
   2. Adjust at the display of the PX/Hermes+ in the menue / setup / maschine parameter / I/O signals / Mode Start the signal to "Level"
   3. Solder a bridge between PIN 6 and 25 at the digital interface
   4. Solder a bridge between PIN 9 and 13 at the digital interface
   5. Solder a bridge between PIN 19 and 20 at the digital interface

Step 1 will set up, that PX is not waiting for a signal "Label is taken" after each and any print!
Step 2 will enable to keep the start signal on high for the complete printing process to the end!
Step 3 will use the internal ground to supply the input signal!
Step 4 will use the print data available signal to start the printer, triggered by a oder download! Please pay attention to that this procedure will also work, if you will send a print queue!
Step 5 will use the internal 24V DC to supply the outputs!

Valid for: PX Series , Hermes + Series , HERMES Q , PX Q

Last change: 15.03.2024 - 10:58

cab Produkttechnik GmbH & Co KG

Wilhelm-Schickard-Str. 14
76131 Karlsruhe
Germany

Call us
Email us
Request support

cab Newsletter

Our cab newsletter will inform you regulary about the topic marking by email. You can cancel the newsletter at any time.

subscribe now!
unsubscribe

Find cab on:

Live Chat